ANCT – Nested Towers – Tilt-down
Height range 4m – 10m
Altron Nested Camera Towers are designed to be a secure mounting solution, where a lattice tower is the preferred mounting option. Cabling through the tower is completely concealed thanks to its patented hinge design and there is a secure access door and treated backboard within the large integrated base post so that connections and equipment are situated inside the tower.
Installation is made easy by the use of a simple bolt frame for setting the holding down bolts and a large entry point into the base post provides clear access for cable ducts.The footprint of the tower is small and the appearance is neat and compact due to the base post ‘nesting’ inside the tower.
ANCT towers give good rigidity and are suitable for exposed locations. Ideal for medium to heavy camera installations or lighter applications where rigidity is paramount, a full range of accessories is available and all tower components are held in stock. ANCT Towers are not ideally suited for public area installations due to their climbable nature.
General Features
Modular construction in 2 metre sections for ease of assembly and installation on site
Large integrated cabinet, allowing equipment mounting and internal cable connections
Patented method of internal cabling pathway, through cabinet and tilt-mechanism, up through tower leg and exiting via conduit exit points.
Simple method of pre-casting base connections – only bolts need to be cast, no other steelwork
Large cable duct entry into bottom of base post
Ideal for restricted access areas
Provides stable mounting platform for all camera types
Demountable winches ensure towers are secure and reduces costs on multiple installations
Enables camera maintenance at ground level, therefore reducing maintenance costs
A wide range of standard Altron Accessories and Brackets available ex stock
Constructed in high tensile steel and hot dip galvanised after fabrication for durability
Option of painting over the galvanised finish in colours available from BS and RAL colour charts
Security Features
Internal cabling
Internal padlock facility
Close fitting flush doors
Solid secure heavy duty door locks
Types of Installation
Industrial and commercial premises
Perimeter detection
Utilities sites
Car parks
Petrochemical sites
Securing compounds
Military and high security sites
Applicable standards
Design
– Wind loading and structural design is carried out using specialist software package in accordance with BS8100 PT1,‘Code of practice for loading’ and BS8100 PT3,‘Code of practice for strength assessment of members of lattice towers and masts’
Material and Finishing
– Structural steel hollow sections EN10219 – EN10025:2004
– Steel flat angles and structural sections EN10025, EN10111, EN 10130
– Foundation bolts Grade 4.6 spun galvanised BS4190, BS3692, DIN931, 934, 601
– Fixings: stainless steel Grade A2, galvanised Grade 4.6 Grade 8.8 BS4190, BS3692, DIN 931, 934, 601
– Hot dipped galvanising after fabrication to ISO 1461
– Painting in BS and RAL colours in accordance with BS4800
Manufacturing Processes
– Welding Procedures conform with BS EN 1011:2009, BS EN 9606-1
Winches
– Wire ropes to BS183:1972, BS EN 13411 3 2004 + A1 2008
– Winches conform to American ASAE standard S361.IT.
Options
Tamper switch /TS
Earth bosses /E-BOSS
Part Numbering
Altron nested towers are supplied with backboard fitted as standard
ANCT/4
ANCT/6
ANCT/8
ANCT/10