Description
Used 0.8 MW MWM CHP power plant including (2) engines rated 400 kW fuelled by biogas and held in soundproof containers. Made in 2011 and still operating 2 days per month. 19442 and 19633 hours of use recorded by February 2024. Equipment list includes:
– (2) MWM TCG 2016 V08 C engines rated 400 kW electrical output, 395 kW thermal output +/- 8%, electrical efficiency 42.8%, thermal efficiency 42.1%. Gas train, gas mixer, generator, voltage stabiliser, power factor controller, coupling, control unit and switchboard.
– exhaust silencer.
– CHP power cabinet.
– heat exchanger cabinet, heat extraction / hydraulic system, plate heat exchanger, surge tank.
– electrical circulation pump for combustion engine.
– mixture cooling.
– exhaust gas heat exchanger
– soundproofed container, 65db(a) in 10M, emergency cooler, engine control system
Each 400kW engine may be available separately; more information on request.